Mechanism of initiating the process of switching a short vacuum gap by an auxiliary spark discharge
Davydov S. G.1, Dolgov A. N.1, Kozlov A. A.1, Maksimov V. A.1, Revazov V. O. 1, Yakubov R. Kh.1
1Dukhov All-Russia Research Institute of Automatics, Moscow, Russia
Email: vniia4@vniia.ru

PDF
The results and analysis of experiments are presented, the purpose of which is to study the mechanism of ignition of a high-voltage arc discharge in a vacuum gap. The results indicate that the development of an arc discharge under the presented conditions is occurs mainly due to the ionization of the residual gas by a flow of overheated electrons with an energy of ~ 100-500 eV from an auxiliary spark discharge. Keywords: vacuum arc, spark discharge, plasma, magnetic field. DOI: 10.61011/TPL.2023.09.56707.19637
Publisher:

Ioffe Institute

Institute Officers:

Director: Sergei V. Ivanov

Contact us:

26 Polytekhnicheskaya, Saint Petersburg 194021, Russian Federation
Fax: +7 (812) 297 1017
Phone: +7 (812) 297 2245